Changelog¶
All notable changes to this project are documented here.
[0.1.1] - 2026-10-24¶
Fixed¶
- Malformed or mismatched Modbus replies now raise
IntelbrasSolarProtocolErrorand reopen the connection. Before, a bareIndexError/ValueErrorescaped. The WiNet-S produced such frames when two clients polled at the same time (observed on the real IONS-5K M5): bad MBAP length, wrong function code, wrong byte count. - The Modbus transaction id now starts at a random value, so two concurrent clients no longer accept each other's replies.
[0.1.0] - 2026-10-24¶
Added¶
IntelbrasSolarClient: async client for Intelbras (Sungrow WiNet-S) inverters withasync_get_status,async_get_inverter_data, and the controlsasync_set_inverter_on,async_set_power_limit_enabled,async_set_power_limitandasync_set_clock.ModbusTcpClient: dependency-free asyncio Modbus TCP client (FC3, FC4, FC6).WiNetClient: reader for the datalogger WebSocket (connect,state,faultanddevicelistservices).InverterStatus,DataloggerStatusandMpptdataclasses, built byparse_registersandparse_datalogger.- Exceptions
IntelbrasSolarError,IntelbrasSolarConnectionErrorandIntelbrasSolarProtocolError.